250W Class II Open Frame Power Supply_Specification
| Model Name | TN19-0250-12-1 | TN19-0250-24-1 | TN19-0250-48-1 | TN19-0250-55-1 | ||
|---|---|---|---|---|---|---|
| Output | Rated Power | 250 W (with 13 CFM) | ||||
| Derating Power | 125W@70°C (Derate linearly from 100% load at +50°C to 50% load at +70°C) | |||||
| Output Voltage | 12 Vdc | 24 Vdc | 48 Vdc | 55 Vdc | ||
| Maximum Output Current | 20.83 A | 10.41 A | 5.20 A | 4.54 A | ||
| Over Current Limit | 105~145 % | 105~145 % | 105~145 % | 105~145 % | ||
| Minimum Output Current | 0 A | 0 A | 0 A | 0 A | ||
| Ripple & Noise | ≦ 1% | |||||
| Hold Up Time | ≧ 10 ms | |||||
| Input | Input Voltage | 90~264 Vac | ||||
| Input Frequency | 47~63 Hz | |||||
| No-load Power Consumption | ≦ 0.15 W | ≦ 0.2 W | ≦ 0.3 W | ≦ 0.3 W | ||
| Power Factor | ≧ 0.95 | |||||
| Efficiency | 0.925 | 0.935 | 0.945 | 0.945 | ||
| Inrush Current | ≦ 45 A @115Vac ; ≦ 90 A @230Vac, 25°C | |||||
| EMC | Surge | 2KV (L/N-G), 1KV (L-N) | ||||
| EMI | EN55032, FCC Part 15 | |||||
| ESD | IEC61000-4-2 | |||||
| Environmental | Operating Temperature | -40~+70 °C | ||||
| Storage Temperature | -40~+85 °C | |||||
| Operating Humidity | 20~90 %RH | |||||
| Storage Humidity | 5~95 %RH | |||||
| Operating Altitude | 5,000 m | |||||
| Others | Dimension (W x L x H) | 50.8 x 101.6 x 21.4 mm (2 x 4 x 0.84 inch) *The height excludes PCB thickness | ||||
| Mean Time Between Failures | ≧ 500,000 hours | |||||
| Certifications | CB, UL | |||||
| Safety Class | Class II | |||||
*Specifications are subject to change without notice
250W Class II Open Frame Power Supply_Mechanical Specfication
250W Class II Open Frame Power Supply_Derating Curve
250W Class II Open Frame Power Supply_Application
- Networking
- Telecom
- POS
- Printer
- IPC
- Industrial
- Sewing machine
- ATM
- Bill counting machine
- Currency detector
- Gaming